# Ampworth Calculators MCP server

Source: https://glimind.com/server/mcp-registry%2Fcom.ampworth%2Fcalculators
Registry id: `mcp-registry/com.ampworth/calculators`
Status: live (checked 2026-11-24T17:03:11.060Z)

## Verdict

Ampworth Calculators MCP server answered 100% of Glimind's liveness checks over 30 days, better than 43% of MCP servers, with 216 ms median handshake and 1 outage in 90 days. Its agent-readiness grade is A (100/100) across 12 tools, costing an agent about 7,315 tokens to load. Checked every few minutes; no tool is ever called.

## Measurements (30 days)

| Metric | Value | Better than |
|---|---|---|
| Uptime, 30 days | 100% | 43% of MCP servers |
| Median handshake latency | 216 ms | 56% of MCP servers |
| p95 handshake latency | 385 ms | — |
| Checks in 30 days | 6,579 | — |
| Outages, 90 days | 1 | — |
| Median recovery | 2 min | — |
| Agent-readiness score | 100/100 (A) | 91% of MCP servers |
| Tools | 12 | — |
| Tool-list size for an agent | ~7,315 tokens | 24% of MCP servers |
| Days observed | 29 | — |

## Install

```json
{
  "mcpServers": {
    "ampworth-calculators-mcp-server": {
      "type": "http",
      "url": "https://ampworth.com/mcp/calculators"
    }
  }
}
```

Claude Code:

```sh
claude mcp add --transport http ampworth-calculators-mcp-server https://ampworth.com/mcp/calculators
```

## Tools (12)

- `connection_route`: Work out which ENA connection procedure a domestic installation of solar panels, batteries or both falls under: connect first and notify the distribution networ
- `heat_pump_noise`: Calculate the sound pressure level an air source heat pump produces at an assessment position, and whether it meets the 37 dB(A) permitted development noise lim
- `heat_pump_running_cost`: Compare what a household spends heating on its current fuel with what the same heat would cost from a heat pump. The heat demand is worked out from the househol
- `heat_pump_size`: Estimate the heat pump a UK house needs, and what it would cost to run against the fuel it burns now. IMPORTANT: MIS 3005-D requires a heat pump to be sized fro
- `hot_water_cylinder`: Work out the daily hot water demand of a dwelling and the size of cylinder a heat pump needs, using the formula in MIS 3005-D 3.5.2 and the BS 6700 guidance rep
- `list_calculators`: Lists every calculator on this server, with the standard behind it and whether it is the whole-system sizing calculator or one of the single-method ones, plus t
- `radiator_flow_temperature`: Work out the flow temperature a heat pump must produce to heat a room through a given radiator, and the resulting MCS Heat Emitter Guide star rating, following 
- `room_heat_loss`: Calculate the design heat loss of a single room in watts, following BS EN 12831 as MIS 3005-D applies it. This is the figure a heat pump is sized from and the f
- `solar_pv_output`: Estimate the annual AC electricity output of a UK solar photovoltaic system, in kWh, using the standard estimation method that MIS 3002 requires every MCS certi
- `solar_pv_self_consumption`: Estimate what proportion of a domestic solar PV system's annual output is consumed in the house and what proportion is exported, using the lookup tables in MGD 
- `solar_pv_shading`: Convert a completed MCS sunpath shading assessment into a shade factor, using the procedure in MGD 005. The MCS sunpath chart is divided into 84 segments, each 
- `solar_pv_system_size`: Work out the solar PV system a UK home needs: the capacity in kWp, the number of panels, the battery to go with it, and what it would do to the electricity bill

Measured by Glimind (https://glimind.com): MCP handshake + tool list only, no tool is ever called. CC BY 4.0.
