## Tools (80)

- `aspirate_ul`
- `autofocus`: Run the configured autofocus device (e.g. a hardware focus lock) once; it moves the focus drive. If the result is outside the Z step or soft limits, the focus i
- `calibrate`
- `clear_calibration`: Delete all stored calibration data (Cal,clear). pH/ORP/DO/EC/RTD return to uncalibrated; CO2/PRS return to their factory calibration. The probe must be recalibr
- `clear_dispensed_volume`: Reset the infused and withdrawn volume accumulators to zero. Only possible while stopped.
- `clear_tare`: Clear the tare memory (tare = 0).
- `close_shutter`: Close the shutter (stop illuminating the sample) and abort any running acquisition.
- `deactivate_modules`: Switch attached modules off: stop heating/cooling (Temperature Module, Thermocycler block and lid, Heater-Shaker heater), stop shaking, and lower Magnetic Modul
- `disable_watchdog`: Cancel watchdog mode 2 (OUT_WD2@0) and stop the background refresh. Watchdog mode 1 has no cancel command; this tool reports an error for it.
- `dispense_ul`
- `enable_watchdog`
- `get_calibration_status`: Report how many calibration points are stored and what that means for this circuit type; for pH also the probe slope (acid/base % of ideal and zero offset in mV
- `get_command_log`: Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done.
- `get_connection_info`: Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first.
- `get_dispensed_volume`: Return the accumulated infused and withdrawn volumes (pump command DIS).
- `get_draft_shield`: Report the position of the motorised draft-shield doors (Excellence/XPR balances only).
- `get_exposure`: Return the camera exposure time in milliseconds.
- `get_identity`: TODO: replace with real tools. See docs/writing-a-server.md.
- `get_info`: Report the circuit type, firmware, device name, supply voltage and last restart reason, LED state, calibration state, temperature compensation and type-specific
- `get_position`: Read the XY stage and focus (Z) positions in micrometres, and which way increasing Z moves the objective.
- `get_protocol`: Show a stored protocol's analysis: whether it is ready to run, analysis errors, the deck layout it expects (labware and modules per slot, pipettes per mount, li
- `get_robot_status`: Report the robot's name, model (Flex/OT-2), software and firmware versions, lights, door and E-stop state, and the current run. Call this first to check the rob
- `get_run_status`
- `get_setpoint`: Read the current temperature setpoint and whether temperature control is running.
- `get_status`: Report what the pump is doing (infusing/withdrawing/stopped/paused, alarms), the syringe diameter, rate, target volume, direction and the accumulated dispensed 
- `get_system_info`: Describe the microscope: loaded devices (camera, stages, shutters, filter wheels...), which device has which role, camera size/bit depth/exposure, pixel size, c
- `get_tare`: Return the weight currently stored in the tare memory.
- `home_robot`: Home all axes of the robot (the gantry and pipettes move to their home positions). Refused while a run is active. Make sure nothing is in the robot's path and t
- `infuse`
- `initialize`
- `list_config_groups`: List Micro-Manager config groups (e.g. Channel, Objective) with their presets and the preset currently active.
- `list_instruments`: List attached pipettes (and the Flex gripper): mount, name, channels, volume range, and whether a tip is detected and calibration data exists.
- `list_modules`: List attached modules (Temperature Module, Heater-Shaker, Thermocycler, Magnetic Module, Absorbance Plate Reader, ...) with live temperatures, targets, shake sp
- `list_protocols`: List protocols stored on the robot (newest last) with their analysis status and result.
- `list_runs`: List recent protocol runs, newest first, with their status.
- `list_syringe_presets`: List the syringe inside diameters from the New Era manual's reference table (BD, Monoject, Terumo, HSW Norm-Ject, Poulten & Graf glass, stainless steel, SGE, Ha
- `log_series`
- `log_weight_series`
- `move_stage_xy`
- `move_z`
- `pause_run`: Pause a running protocol. The robot finishes its current step and then holds; resume_run continues it.
- `read_temperatures`: Read the bath temperature, the heating/cooling power in % and the safety-sensor temperature, and optionally the external Pt100 sensor.
- `read_value`: Take one reading (about 1 s) and return every enabled output with its unit: pH; ORP in mV; DO in mg/L (and % saturation if enabled); EC in µS/cm plus TDS (ppm),
- `read_weight`
- `reconnect`: Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged).
- `resume_run`
- `run_internal_adjustment`: Adjust (calibrate) the balance with its built-in reference weight (MT-SICS C3). The pan must be empty and the balance undisturbed. Takes roughly 1-3 minutes.
- `set_config`
- `set_do_compensation`
- `set_exposure`: Set the camera exposure time (ms). Longer exposures give brighter images but more photobleaching. Returns the exposure the camera accepted.
- `set_led`: Turn the circuit's status LED on or off. Returns the new LED state.
- `set_lights`: Turn the robot's deck (rail) lights on or off.
- `set_objective`
- `set_probe_constant`: EC circuits only: set the conductivity probe's cell constant K to match the probe (printed on it). Recalibrate after changing it. Returns the K now in use.
- `set_setpoint`: Set the circulator's temperature setpoint (out_sp_00). If temperature control is running, the circulator starts heating or cooling to it immediately. Refused ou
- `set_speed`: Set the stirring speed setpoint (OUT_SP_4). Does not start the motor; if it is already running, the speed changes immediately. Refused above `max_speed_rpm` (an
- `set_syringe`
- `set_tare_preset`
- `set_temperature`: Set the hotplate temperature setpoint (OUT_SP_1). With an external probe connected this is the target temperature of the medium. Does not start heating; if heat
- `set_temperature_compensation`: Set the sample temperature used to compensate pH, EC or DO readings (T,n; always °C). Not retained through a power cycle. Returns the value the circuit now uses
- `set_valve`
- `show_message`: Show a short message on the balance display (e.g. 'Add sample 3'). Use `show_weight_display` to return to the normal weight display.
- `show_weight_display`: Switch the balance display back to showing the weight.
- `start_circulation`: Start temperature control (out_mode_05 1): the pump runs and the bath heats or cools to the setpoint, which is checked against the safety limits first (it may h
- `start_heating`: Switch the hotplate heater on (START_1). It heats towards the current setpoint, which is checked against `max_temperature_c` first. Make sure the vessel and its
- `start_run`
- `start_stirring`: Start the stirring motor (START_4) at the current speed setpoint, which is checked against `max_speed_rpm` first. Make sure the stir bar or impeller is in place
- `stop_all`: Emergency stop: switch the heater off (hotplates) and stop the motor. Every stop command is sent even if one of them fails. Also ends a running `wait_for_temper
- `stop_circulation`: Stop temperature control and the pump (out_mode_05 0), then confirm with in_mode_05. Also ends a running `wait_for_temperature`. The bath stays hot/cold after s
- `stop_heating`: Switch the hotplate heater off (STOP_1). Stirring continues. The plate stays hot for a long time after switching off.
- `stop_pump`: Stop the pump immediately (STP). A paused program is also cancelled so it cannot resume.
- `stop_run`: Stop (cancel) a run immediately. A stopped run cannot be resumed; the robot homes and drops any attached tips into the trash. Use this whenever something looks 
- `stop_stage`: Immediately stop XY and Z stage motion and abort any z-stack or time-lapse in progress.
- `stop_stirring`: Stop the stirring motor (STOP_4). Heating (if on) continues.
- `tare`: Tare the balance: store the current load (e.g. an empty container) as the tare weight. Returns the stored tare weight.
- `terminate`: Stop any plunger move, loop or delay immediately (DT command T). A valve move in progress still completes. Re-initialize afterwards: the plunger may have lost s
- `upload_protocol`
- `wait_for_temperature`
- `withdraw`
- `zero`: Zero the balance with the current load. Also clears the tare memory.